{"id":1164,"date":"2021-07-27T16:07:16","date_gmt":"2021-07-27T08:07:16","guid":{"rendered":"https:\/\/kelly.anjun.com.tw\/?page_id=1164"},"modified":"2021-11-08T11:41:59","modified_gmt":"2021-11-08T03:41:59","slug":"compact-ir-spectrometer","status":"publish","type":"page","link":"https:\/\/www.anjun.com.tw\/en\/%e9%9b%b7%e5%b0%84\/%e9%9b%b7%e5%b0%84%e9%80%b1%e9%82%8a%e8%a8%ad%e5%82%99%e9%8a%b7%e5%94%ae\/solar-ls%e9%9b%b7%e5%b0%84\/spectral-instruments\/compact-spectrometers\/compact-ir-spectrometer\/","title":{"rendered":"COMPACT IR-SPECTROMETER"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"1164\" class=\"elementor elementor-1164\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-e63de91 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"e63de91\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-73d580f\" data-id=\"73d580f\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-ce122eb elementor-widget elementor-widget-heading\" data-id=\"ce122eb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Model S90-IR<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-c00e235 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"c00e235\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-ea851f3\" data-id=\"ea851f3\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-a6293f1 elementor-tabs-view-horizontal elementor-widget elementor-widget-tabs\" data-id=\"a6293f1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"tabs.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-tabs\">\n\t\t\t<div class=\"elementor-tabs-wrapper\" role=\"tablist\" >\n\t\t\t\t\t\t\t\t\t<div id=\"elementor-tab-title-1741\" class=\"elementor-tab-title elementor-tab-desktop-title\" aria-selected=\"true\" data-tab=\"1\" role=\"tab\" tabindex=\"0\" aria-controls=\"elementor-tab-content-1741\" aria-expanded=\"false\">DESCRIPTION<\/div>\n\t\t\t\t\t\t\t\t\t<div id=\"elementor-tab-title-1742\" class=\"elementor-tab-title elementor-tab-desktop-title\" aria-selected=\"false\" data-tab=\"2\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1742\" aria-expanded=\"false\">SPECIFICATIONS<\/div>\n\t\t\t\t\t\t\t\t\t<div id=\"elementor-tab-title-1743\" class=\"elementor-tab-title elementor-tab-desktop-title\" aria-selected=\"false\" data-tab=\"3\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1743\" aria-expanded=\"false\">OPTIONS & ACCESSORIES<\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t<div class=\"elementor-tabs-content-wrapper\" role=\"tablist\" aria-orientation=\"vertical\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-tab-title elementor-tab-mobile-title\" aria-selected=\"true\" data-tab=\"1\" role=\"tab\" tabindex=\"0\" aria-controls=\"elementor-tab-content-1741\" aria-expanded=\"false\">DESCRIPTION<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1741\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" role=\"tabpanel\" aria-labelledby=\"elementor-tab-title-1741\" tabindex=\"0\" hidden=\"false\"><div class=\"container feauteres\"><div class=\"row\"><div class=\"col-12\"><h4 class=\"title text-left\"><span style=\"color: #000000;\">FEATURES<\/span><\/h4><p><span style=\"color: #000000;\">The compact high-sensitivity spectrometer S90-IR contains a non-cooled linear InGaAs image sensor, and is recommended for any spectroscopic applications in the NIR spectrum range such as fluorescence, reflection, transmittance, photometric measurements and other researches that do not require long-time signal storage.<\/span><\/p><\/div><\/div><\/div><div class=\"wrapper product-advantages-wr\"><div class=\"container\"><div class=\"row\"><div class=\"col-6 left\"><ul><li><p><span style=\"color: #000000;\">NON-COOLED INGAAS DETECTOR<\/span><\/p><\/li><li><p><span style=\"color: #000000;\">COMPACT MONOLITHIC CASE ENSURES STABILITY OF PARAMETERS<\/span><\/p><\/li><li><p><span style=\"color: #000000;\">DIFFRACTION GRATING, SPECTRAL RANGE AND RESOLUTION ARE CHOSEN AT THE TIME OF ORDER PLACING<\/span><\/p><\/li><li><p><span style=\"color: #000000;\">USER-FRIENDLY INTERFACE COMPATIBLE WITH WINDOWS XP, WINDOWS 7\/8\/10<\/span><\/p><\/li><\/ul><h2><span style=\"color: #000000;\">DESCRIPTION<\/span><\/h2><p><span style=\"color: #000000;\">The high-aperture optical scheme of the S90-IR has no moving parts.\u00a0The S90-IR case is monolithic and ensures long-time stability of parameters.<\/span><\/p><p><span style=\"color: #000000;\"><img decoding=\"async\" src=\"https:\/\/www.anjun.com.tw\/wp-content\/uploads\/2019\/01\/S90-IR_1-300x208.png\" \/> <img decoding=\"async\" src=\"https:\/\/www.anjun.com.tw\/wp-content\/uploads\/2019\/01\/S90-IR_2-300x208.png\" \/> <img decoding=\"async\" src=\"https:\/\/www.anjun.com.tw\/wp-content\/uploads\/2019\/01\/S90-IR_3-300x208.png\" \/> <img decoding=\"async\" src=\"https:\/\/www.anjun.com.tw\/wp-content\/uploads\/2019\/01\/S90-IR_4-300x171.png\" \/><\/span><\/p><p><span style=\"color: #000000;\">The S90-IR spectrometer is easy and convenient to use: it is calibrated by the manufacturer, is controlled and powered from the PC via Full-Speed USB interface.\u00a0Light input with the use of quartz optical fiber provides flexibility of instrumentation arrangement. The spectrometer has the entrance slit of fixed width and may be used without optical fiber.<\/span><\/p><p><span style=\"color: #000000;\"><img decoding=\"async\" class=\"aligncenter\" src=\"https:\/\/www.anjun.com.tw\/wp-content\/uploads\/2019\/01\/s90-1.png\" \/><\/span><\/p><p style=\"text-align: center;\"><span style=\"color: #000000;\"><em>Spectral curve of sensitivity of the InGaAs linear image sensor, G9204-512D model<\/em><\/span><\/p><p style=\"text-align: center;\"><span style=\"color: #000000;\"><img decoding=\"async\" src=\"https:\/\/www.anjun.com.tw\/wp-content\/uploads\/2019\/01\/S90-IR_dim.jpg\" \/><\/span><\/p><p style=\"text-align: center;\"><span style=\"color: #000000;\"><em>Overall dimensions of the S90-IR spectrometer<\/em><\/span><\/p><\/div><\/div><\/div><\/div><\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-tab-title elementor-tab-mobile-title\" aria-selected=\"false\" data-tab=\"2\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1742\" aria-expanded=\"false\">SPECIFICATIONS<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1742\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"2\" role=\"tabpanel\" aria-labelledby=\"elementor-tab-title-1742\" tabindex=\"0\" hidden=\"hidden\"><h4><span style=\"color: #000000;\">SPECIFICATIONS<\/span><\/h4><table border=\"1\"><thead><tr><td style=\"text-align: center;\"><span style=\"color: #000000;\"><strong>SPECTROMETER MODEL<\/strong><\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\"><strong>S90-IR<\/strong><\/span><\/td><\/tr><\/thead><tbody><tr><td style=\"text-align: center;\"><span style=\"color: #000000;\">Spectral range, nm<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">780 \u2013 1700<\/span><\/td><\/tr><tr><td style=\"text-align: center;\"><span style=\"color: #000000;\">Focal length, mm<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">87.7<\/span><\/td><\/tr><tr><td style=\"text-align: center;\"><span style=\"color: #000000;\">F\/number<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">1 : 7.7<\/span><\/td><\/tr><tr><td style=\"text-align: center;\"><span style=\"color: #000000;\">Entrance slit, mm<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">0.020 \u00d7 3<\/span><\/td><\/tr><tr><td style=\"text-align: center;\"><span style=\"color: #000000;\">Spectral resolution<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">depends on selected diffraction grating (see table below)<\/span><\/td><\/tr><tr><td style=\"text-align: center;\"><span style=\"color: #000000;\">Detector model<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\"><strong>G9204-512D<\/strong><\/span><\/td><\/tr><tr><td style=\"text-align: center;\"><span style=\"color: #000000;\">Number of pixels<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">512<\/span><\/td><\/tr><tr><td style=\"text-align: center;\"><span style=\"color: #000000;\">Pixel size, \u03bcm<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">25 \u00d7 500<\/span><\/td><\/tr><tr><td style=\"text-align: center;\"><span style=\"color: #000000;\">Active area size, mm<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">12.8 \u00d7 0.5<\/span><\/td><\/tr><tr><td style=\"text-align: center;\"><span style=\"color: #000000;\">Maximum spectral sensitivity , nm<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">1550<\/span><\/td><\/tr><tr><td style=\"text-align: center;\"><span style=\"color: #000000;\">Non-uniformity of sensitivity\u00a0<sup>1), 4)<\/sup><\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">\u00b1 5 %<\/span><\/td><\/tr><tr><td style=\"text-align: center;\"><span style=\"color: #000000;\">Anti-blooming\u00a0<sup>2)<\/sup><\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">Yes<\/span><\/td><\/tr><tr><td style=\"text-align: center;\"><span style=\"color: #000000;\">ADC Resolution<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">16bit, 125 kHz<\/span><\/td><\/tr><tr><td style=\"text-align: center;\"><span style=\"color: #000000;\">Mean-square reading noise, ADC counts\u00a0<sup>4)<\/sup><\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">&lt; 6<\/span><\/td><\/tr><tr><td style=\"text-align: center;\"><span style=\"color: #000000;\">Dynamic range<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">~ 12000 : 1<\/span><\/td><\/tr><tr><td style=\"text-align: center;\"><span style=\"color: #000000;\">Exposure time<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">8.2 ms \u2013 0.7 s\u00a0<sup>3), 4)<\/sup><\/span><\/td><\/tr><tr><td style=\"text-align: center;\"><span style=\"color: #000000;\">Frame processing time, ms<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">4.1<\/span><\/td><\/tr><tr><td style=\"text-align: center;\"><span style=\"color: #000000;\">Thermoelectric cooling<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">No<\/span><\/td><\/tr><tr><td style=\"text-align: center;\"><span style=\"color: #000000;\">Operating temperature<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">10 \u2013 30 \u00b0\u0421<\/span><\/td><\/tr><tr><td style=\"text-align: center;\"><span style=\"color: #000000;\">Computer interface<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">Full Speed USB<\/span><\/td><\/tr><tr><td style=\"text-align: center;\"><span style=\"color: #000000;\">Triggering<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">internal \/ external<\/span><\/td><\/tr><tr><td style=\"text-align: center;\"><span style=\"color: #000000;\">Requirements to external trigger pulse<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">BNC-58 connector, positive polarity, 3-15 VDC amplitude, 5-20 \u03bcs pulse duration FWHM<\/span><\/td><\/tr><tr><td style=\"text-align: center;\"><span style=\"color: #000000;\">Parameters of the S90-IR trigger pulses<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">positive polarity, 4-5 VDC amplitude, 10 \u03bcs pulse duration FWHM<\/span><\/td><\/tr><tr><td style=\"text-align: center;\"><span style=\"color: #000000;\">Optical input<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">\u2014 direct input through the S90-IR entrance slit<\/span><br \/><span style=\"color: #000000;\">\u2014 Optical Fiber : 0.6 mm diameter, 1m length, SMA-905 connector<\/span><\/td><\/tr><tr><td style=\"text-align: center;\"><span style=\"color: #000000;\">Dimensions, mm<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">142 \u00d7 110 \u00d7 80<\/span><\/td><\/tr><tr><td style=\"text-align: center;\"><span style=\"color: #000000;\">Weight, kg<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">1.2<\/span><\/td><\/tr><\/tbody><\/table><p class=\"i\"><span style=\"color: #000000;\"><sup>1)<\/sup>\u00a0Signal level \u2014 50% of saturation. Exposure time is 10 ms.<\/span><\/p><p class=\"i\"><span style=\"color: #000000;\"><sup>2)<\/sup>\u00a0Anti-blooming \u2013 sensor\u2019s feature eliminating overflow of charges from over-exposed pixels to neighboring ones.<\/span><\/p><p class=\"i\"><span style=\"color: #000000;\"><sup>3)<\/sup>\u00a0Maximum exposure time is deemed to be the time at which dark signal makes up 25% of the dynamic range at the ambient temperature +25\u00b0C.<\/span><\/p><p class=\"i\"><span style=\"color: #000000;\"><sup>4)<\/sup>\u00a0The detector provides two operation modes: wide dynamic range or high sensitivity. Parameters indicated in the table are for the wide dynamic range mode.<\/span><\/p><h2><span style=\"color: #000000;\">Recommendations for choosing a diffraction grating<\/span><\/h2><p><span style=\"color: #000000;\">When placing an order, you should choose the number of grating lines (i.e. spectral resolution of your instrument), as well as the spectral range for operation. For your convenience the table below contains average values of grating dispersion, spectral resolution and simultaneous recording interval of the CCD-detector.<\/span><\/p><table border=\"1\"><thead><tr><td style=\"text-align: center;\"><span style=\"color: #000000;\">DIFFRACTION GRATINGS, LINES\/MM<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">150<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">200<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">300<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">400<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">600<\/span><\/td><\/tr><\/thead><tbody><tr><td style=\"text-align: center;\"><span style=\"color: #000000;\">\u2014 spectral range of InGaAs detector sensitivity, nm<\/span><\/td><td style=\"text-align: center;\" colspan=\"5\"><span style=\"color: #000000;\">780 \u2014 1700 nm<\/span><\/td><\/tr><tr><td style=\"text-align: center;\"><span style=\"color: #000000;\">\u2014 multichannel array bandpass (average), nm<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">954<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">710<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">464<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">320<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">210<\/span><\/td><\/tr><tr><td style=\"text-align: center;\"><span style=\"color: #000000;\">\u2014 reciprocal linear dispersion (average), nm\/mm<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">74.5<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">55.5<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">36.3<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">26.5<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">16.6<\/span><\/td><\/tr><tr><td style=\"text-align: center;\"><span style=\"color: #000000;\">\u2014 spectral resolution (average), nm<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">4.6<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">3.4<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">2.3<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">1.7<\/span><\/td><td style=\"text-align: center;\"><span style=\"color: #000000;\">1.0<\/span><\/td><\/tr><\/tbody><\/table><p><span style=\"color: #000000;\"><strong>EXAMPLE<\/strong>: If you are interested in the grating 200 lines\/mm (average spectral resolution 3.4nm), it remains to choose a location of simultaneous recording interval 710nm within the possible spectral range of 780-1700nm, for instance, the S90-IR spectrometer operating in the range 990-1700nm with 3.4nm resolution.<\/span><\/p><p><style type=\"text\/css\">\n<!-- table{ border-collapse:separate; collapse;border:1px solid black; } td{ collapse;border:1px solid black; } --><br \/>\n<\/style><\/p><\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-tab-title elementor-tab-mobile-title\" aria-selected=\"false\" data-tab=\"3\" role=\"tab\" tabindex=\"-1\" aria-controls=\"elementor-tab-content-1743\" aria-expanded=\"false\">OPTIONS & ACCESSORIES<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1743\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"3\" role=\"tabpanel\" aria-labelledby=\"elementor-tab-title-1743\" tabindex=\"0\" hidden=\"hidden\"><h4 class=\"title-tab title text-left\"><span style=\"color: #000000;\">OPTIONS &amp; ACCESSORIES<\/span><\/h4><p><span style=\"color: #000000;\">Upon Your request, the S90-IR spectrometer can be equipped with high-order separating compound filter designed for operation with broadband spectra.<\/span><\/p><p><span style=\"color: #000000;\">The S90-IR spectrometer can be supplied with VUV or FWF\u00a0<strong>optical fibers<\/strong>\u00a0with various lengths.<\/span><\/p><p><span style=\"color: #000000;\">The S90-IR spectrometer has a wide range of\u00a0<strong>options and accessories<\/strong>\u00a0that allow efficient collection of light from the sample located at a finite distance and in infinity:<\/span><\/p><p><span style=\"color: #000000;\"><strong>\u2022 Condenser PS-2<\/strong>\u00a0\u00a0is designed for collecting light from a sample located at 40 mm distance within a wide spectral range and its effective transmission into an optical fiber or onto an entrance slit of a spectral device.<\/span><\/p><p><span style=\"color: #000000;\"><strong>\u2022 Condenser PS-3<\/strong>\u00a0is designed for collecting light from a sample located at 29 mm distance within a wide aperture angle and its further transmission into an optical fiber or onto an entrance slit of a spectral device.<\/span><\/p><p><span style=\"color: #000000;\"><strong>\u2022 Adapter FA-1<\/strong>\u00a0\u2013 achromatic adapter for focusing parallel beam to a fiber with 3D-alignment.<\/span><\/p><p><span style=\"color: #000000;\"><strong>\u2022 Adapter FA-2<\/strong>\u00a0\u2013 achromatic adapter for focusing parallel beam to a fiber with an axial alignment.<\/span><\/p><p><span style=\"color: #000000;\"><strong>\u2022 Cassegrain objectives<\/strong>\u00a0allow collecting light from objects located at a distance of 3.5m to infinity.<\/span><\/p><p><span style=\"color: #000000;\"><strong>\u2022 Diffuse attenuator FA-3<\/strong>\u00a0is designed to attenuate the laser beam while delivering it to a fiber.<\/span><\/p><p><span style=\"color: #000000;\"><strong>\u2022<\/strong>\u00a0The S90-IR spectrometer can be supplied with\u00a0<strong>a cuvette holder FA-10<\/strong>\u00a0and with\u00a0<strong>fiber-optics immersion probes DipProbes<\/strong>\u00a0with a set of interchangeable tips for liquid handling.<\/span><\/p><p><span style=\"color: #000000;\"><strong>Contact a SOLAR LS specialist to select the complete set of the device that meets the requirement of your instrument complex in the best way.<\/strong><\/span><\/p><\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-b24c3e8 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"b24c3e8\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-9d21805\" data-id=\"9d21805\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-eab95d8 elementor-widget elementor-widget-spacer\" data-id=\"eab95d8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-314a7b7 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"314a7b7\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-6364d2e\" data-id=\"6364d2e\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-d038030 elementor-widget elementor-widget-text-editor\" data-id=\"d038030\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"text-align: center;\">SOLARLS\u7684\u6240\u6709\u8cc7\u8a0a\u4f86\u81eaSOLARLS\u7db2\u9801\uff0c\u6240\u6709\u7248\u6b0a\u6b78SOLARLS\uff0c\u7e41\u9ad4\u5b57\u7248\u6b0a\u5c6c\u5b89\u5747\u79d1\u6280\u3002<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Model S90-IR DESCRIPTION SPECIFICATIONS OPTIONS &amp; A&hellip;&nbsp;<a href=\"https:\/\/www.anjun.com.tw\/en\/%e9%9b%b7%e5%b0%84\/%e9%9b%b7%e5%b0%84%e9%80%b1%e9%82%8a%e8%a8%ad%e5%82%99%e9%8a%b7%e5%94%ae\/solar-ls%e9%9b%b7%e5%b0%84\/spectral-instruments\/compact-spectrometers\/compact-ir-spectrometer\/\" class=\"\" rel=\"bookmark\">Read More &raquo;<span class=\"screen-reader-text\">COMPACT IR-SPECTROMETER<\/span><\/a><\/p>","protected":false},"author":2,"featured_media":0,"parent":1117,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"off","neve_meta_content_width":70,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"class_list":["post-1164","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>COMPACT IR-SPECTROMETER &#060; \u5b89\u5747\u79d1\u6280\u6709\u9650\u516c\u53f8<\/title>\n<meta name=\"description\" content=\"The compact high-sensitivity spectrometer S90-IR contains a non-cooled linear InGaAs image sensor, and is recommended for any ...\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.anjun.com.tw\/en\/\u96f7\u5c04\/\u96f7\u5c04\u9031\u908a\u8a2d\u5099\u92b7\u552e\/solar-ls\u96f7\u5c04\/spectral-instruments\/compact-spectrometers\/compact-ir-spectrometer\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"COMPACT IR-SPECTROMETER &#060; \u5b89\u5747\u79d1\u6280\u6709\u9650\u516c\u53f8\" \/>\n<meta property=\"og:description\" content=\"The compact high-sensitivity spectrometer S90-IR contains a non-cooled linear InGaAs image sensor, and is recommended for any ...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.anjun.com.tw\/en\/\u96f7\u5c04\/\u96f7\u5c04\u9031\u908a\u8a2d\u5099\u92b7\u552e\/solar-ls\u96f7\u5c04\/spectral-instruments\/compact-spectrometers\/compact-ir-spectrometer\/\" \/>\n<meta property=\"og:site_name\" content=\"\u5b89\u5747\u79d1\u6280\u6709\u9650\u516c\u53f8\" \/>\n<meta property=\"article:modified_time\" content=\"2021-11-08T03:41:59+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/www.anjun.com.tw\/wp-content\/uploads\/2019\/01\/S90-IR_1-300x208.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.anjun.com.tw\/%e9%9b%b7%e5%b0%84\/%e9%9b%b7%e5%b0%84%e9%80%b1%e9%82%8a%e8%a8%ad%e5%82%99%e9%8a%b7%e5%94%ae\/solar-ls%e9%9b%b7%e5%b0%84\/spectral-instruments\/compact-spectrometers\/compact-ir-spectrometer\/\",\"url\":\"https:\/\/www.anjun.com.tw\/%e9%9b%b7%e5%b0%84\/%e9%9b%b7%e5%b0%84%e9%80%b1%e9%82%8a%e8%a8%ad%e5%82%99%e9%8a%b7%e5%94%ae\/solar-ls%e9%9b%b7%e5%b0%84\/spectral-instruments\/compact-spectrometers\/compact-ir-spectrometer\/\",\"name\":\"COMPACT IR-SPECTROMETER &#060; \u5b89\u5747\u79d1\u6280\u6709\u9650\u516c\u53f8\",\"isPartOf\":{\"@id\":\"https:\/\/www.anjun.com.tw\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.anjun.com.tw\/%e9%9b%b7%e5%b0%84\/%e9%9b%b7%e5%b0%84%e9%80%b1%e9%82%8a%e8%a8%ad%e5%82%99%e9%8a%b7%e5%94%ae\/solar-ls%e9%9b%b7%e5%b0%84\/spectral-instruments\/compact-spectrometers\/compact-ir-spectrometer\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.anjun.com.tw\/%e9%9b%b7%e5%b0%84\/%e9%9b%b7%e5%b0%84%e9%80%b1%e9%82%8a%e8%a8%ad%e5%82%99%e9%8a%b7%e5%94%ae\/solar-ls%e9%9b%b7%e5%b0%84\/spectral-instruments\/compact-spectrometers\/compact-ir-spectrometer\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.anjun.com.tw\/wp-content\/uploads\/2019\/01\/S90-IR_1-300x208.png\",\"datePublished\":\"2021-07-27T08:07:16+00:00\",\"dateModified\":\"2021-11-08T03:41:59+00:00\",\"description\":\"The compact high-sensitivity spectrometer S90-IR contains a non-cooled linear InGaAs image sensor, and is recommended for any ...\",\"breadcrumb\":{\"@id\":\"https:\/\/www.anjun.com.tw\/%e9%9b%b7%e5%b0%84\/%e9%9b%b7%e5%b0%84%e9%80%b1%e9%82%8a%e8%a8%ad%e5%82%99%e9%8a%b7%e5%94%ae\/solar-ls%e9%9b%b7%e5%b0%84\/spectral-instruments\/compact-spectrometers\/compact-ir-spectrometer\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.anjun.com.tw\/%e9%9b%b7%e5%b0%84\/%e9%9b%b7%e5%b0%84%e9%80%b1%e9%82%8a%e8%a8%ad%e5%82%99%e9%8a%b7%e5%94%ae\/solar-ls%e9%9b%b7%e5%b0%84\/spectral-instruments\/compact-spectrometers\/compact-ir-spectrometer\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.anjun.com.tw\/%e9%9b%b7%e5%b0%84\/%e9%9b%b7%e5%b0%84%e9%80%b1%e9%82%8a%e8%a8%ad%e5%82%99%e9%8a%b7%e5%94%ae\/solar-ls%e9%9b%b7%e5%b0%84\/spectral-instruments\/compact-spectrometers\/compact-ir-spectrometer\/#primaryimage\",\"url\":\"https:\/\/www.anjun.com.tw\/wp-content\/uploads\/2019\/01\/S90-IR_1-300x208.png\",\"contentUrl\":\"https:\/\/www.anjun.com.tw\/wp-content\/uploads\/2019\/01\/S90-IR_1-300x208.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.anjun.com.tw\/%e9%9b%b7%e5%b0%84\/%e9%9b%b7%e5%b0%84%e9%80%b1%e9%82%8a%e8%a8%ad%e5%82%99%e9%8a%b7%e5%94%ae\/solar-ls%e9%9b%b7%e5%b0%84\/spectral-instruments\/compact-spectrometers\/compact-ir-spectrometer\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9801\",\"item\":\"https:\/\/www.anjun.com.tw\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u96f7\u5c04\",\"item\":\"https:\/\/www.anjun.com.tw\/%e9%9b%b7%e5%b0%84\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"\u96f7\u5c04\u9031\u908a\u8a2d\u5099\u92b7\u552e\",\"item\":\"https:\/\/www.anjun.com.tw\/%e9%9b%b7%e5%b0%84\/%e9%9b%b7%e5%b0%84%e9%80%b1%e9%82%8a%e8%a8%ad%e5%82%99%e9%8a%b7%e5%94%ae\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"SOLAR LS\u96f7\u5c04\",\"item\":\"https:\/\/www.anjun.com.tw\/%e9%9b%b7%e5%b0%84\/%e9%9b%b7%e5%b0%84%e9%80%b1%e9%82%8a%e8%a8%ad%e5%82%99%e9%8a%b7%e5%94%ae\/solar-ls%e9%9b%b7%e5%b0%84\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"SPECTRAL INSTRUMENTS\",\"item\":\"https:\/\/www.anjun.com.tw\/%e9%9b%b7%e5%b0%84\/%e9%9b%b7%e5%b0%84%e9%80%b1%e9%82%8a%e8%a8%ad%e5%82%99%e9%8a%b7%e5%94%ae\/solar-ls%e9%9b%b7%e5%b0%84\/spectral-instruments\/\"},{\"@type\":\"ListItem\",\"position\":6,\"name\":\"COMPACT SPECTROMETERS\",\"item\":\"https:\/\/www.anjun.com.tw\/%e9%9b%b7%e5%b0%84\/%e9%9b%b7%e5%b0%84%e9%80%b1%e9%82%8a%e8%a8%ad%e5%82%99%e9%8a%b7%e5%94%ae\/solar-ls%e9%9b%b7%e5%b0%84\/spectral-instruments\/compact-spectrometers\/\"},{\"@type\":\"ListItem\",\"position\":7,\"name\":\"COMPACT IR-SPECTROMETER\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.anjun.com.tw\/#website\",\"url\":\"https:\/\/www.anjun.com.tw\/\",\"name\":\"\u5b89\u5747\u79d1\u6280\u6709\u9650\u516c\u53f8\",\"description\":\"ANJUN TECHNOLOGY CO., LTD.\",\"publisher\":{\"@id\":\"https:\/\/www.anjun.com.tw\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.anjun.com.tw\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.anjun.com.tw\/#organization\",\"name\":\"\u5b89\u5747\u79d1\u6280\u6709\u9650\u516c\u53f8\",\"url\":\"https:\/\/www.anjun.com.tw\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.anjun.com.tw\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.anjun.com.tw\/wp-content\/uploads\/2021\/08\/\u65b0LOGO123-03-1.png\",\"contentUrl\":\"https:\/\/www.anjun.com.tw\/wp-content\/uploads\/2021\/08\/\u65b0LOGO123-03-1.png\",\"width\":1000,\"height\":485,\"caption\":\"\u5b89\u5747\u79d1\u6280\u6709\u9650\u516c\u53f8\"},\"image\":{\"@id\":\"https:\/\/www.anjun.com.tw\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"COMPACT IR-SPECTROMETER &#060; \u5b89\u5747\u79d1\u6280\u6709\u9650\u516c\u53f8","description":"The compact high-sensitivity spectrometer S90-IR contains a non-cooled linear InGaAs image sensor, and is recommended for any ...","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.anjun.com.tw\/en\/\u96f7\u5c04\/\u96f7\u5c04\u9031\u908a\u8a2d\u5099\u92b7\u552e\/solar-ls\u96f7\u5c04\/spectral-instruments\/compact-spectrometers\/compact-ir-spectrometer\/","og_locale":"en_US","og_type":"article","og_title":"COMPACT IR-SPECTROMETER &#060; \u5b89\u5747\u79d1\u6280\u6709\u9650\u516c\u53f8","og_description":"The compact high-sensitivity spectrometer S90-IR contains a non-cooled linear InGaAs image sensor, and is recommended for any ...","og_url":"https:\/\/www.anjun.com.tw\/en\/\u96f7\u5c04\/\u96f7\u5c04\u9031\u908a\u8a2d\u5099\u92b7\u552e\/solar-ls\u96f7\u5c04\/spectral-instruments\/compact-spectrometers\/compact-ir-spectrometer\/","og_site_name":"\u5b89\u5747\u79d1\u6280\u6709\u9650\u516c\u53f8","article_modified_time":"2021-11-08T03:41:59+00:00","og_image":[{"url":"http:\/\/www.anjun.com.tw\/wp-content\/uploads\/2019\/01\/S90-IR_1-300x208.png","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.anjun.com.tw\/%e9%9b%b7%e5%b0%84\/%e9%9b%b7%e5%b0%84%e9%80%b1%e9%82%8a%e8%a8%ad%e5%82%99%e9%8a%b7%e5%94%ae\/solar-ls%e9%9b%b7%e5%b0%84\/spectral-instruments\/compact-spectrometers\/compact-ir-spectrometer\/","url":"https:\/\/www.anjun.com.tw\/%e9%9b%b7%e5%b0%84\/%e9%9b%b7%e5%b0%84%e9%80%b1%e9%82%8a%e8%a8%ad%e5%82%99%e9%8a%b7%e5%94%ae\/solar-ls%e9%9b%b7%e5%b0%84\/spectral-instruments\/compact-spectrometers\/compact-ir-spectrometer\/","name":"COMPACT IR-SPECTROMETER &#060; \u5b89\u5747\u79d1\u6280\u6709\u9650\u516c\u53f8","isPartOf":{"@id":"https:\/\/www.anjun.com.tw\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.anjun.com.tw\/%e9%9b%b7%e5%b0%84\/%e9%9b%b7%e5%b0%84%e9%80%b1%e9%82%8a%e8%a8%ad%e5%82%99%e9%8a%b7%e5%94%ae\/solar-ls%e9%9b%b7%e5%b0%84\/spectral-instruments\/compact-spectrometers\/compact-ir-spectrometer\/#primaryimage"},"image":{"@id":"https:\/\/www.anjun.com.tw\/%e9%9b%b7%e5%b0%84\/%e9%9b%b7%e5%b0%84%e9%80%b1%e9%82%8a%e8%a8%ad%e5%82%99%e9%8a%b7%e5%94%ae\/solar-ls%e9%9b%b7%e5%b0%84\/spectral-instruments\/compact-spectrometers\/compact-ir-spectrometer\/#primaryimage"},"thumbnailUrl":"https:\/\/www.anjun.com.tw\/wp-content\/uploads\/2019\/01\/S90-IR_1-300x208.png","datePublished":"2021-07-27T08:07:16+00:00","dateModified":"2021-11-08T03:41:59+00:00","description":"The compact high-sensitivity spectrometer S90-IR contains a non-cooled linear InGaAs image sensor, and is recommended for any ...","breadcrumb":{"@id":"https:\/\/www.anjun.com.tw\/%e9%9b%b7%e5%b0%84\/%e9%9b%b7%e5%b0%84%e9%80%b1%e9%82%8a%e8%a8%ad%e5%82%99%e9%8a%b7%e5%94%ae\/solar-ls%e9%9b%b7%e5%b0%84\/spectral-instruments\/compact-spectrometers\/compact-ir-spectrometer\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.anjun.com.tw\/%e9%9b%b7%e5%b0%84\/%e9%9b%b7%e5%b0%84%e9%80%b1%e9%82%8a%e8%a8%ad%e5%82%99%e9%8a%b7%e5%94%ae\/solar-ls%e9%9b%b7%e5%b0%84\/spectral-instruments\/compact-spectrometers\/compact-ir-spectrometer\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.anjun.com.tw\/%e9%9b%b7%e5%b0%84\/%e9%9b%b7%e5%b0%84%e9%80%b1%e9%82%8a%e8%a8%ad%e5%82%99%e9%8a%b7%e5%94%ae\/solar-ls%e9%9b%b7%e5%b0%84\/spectral-instruments\/compact-spectrometers\/compact-ir-spectrometer\/#primaryimage","url":"https:\/\/www.anjun.com.tw\/wp-content\/uploads\/2019\/01\/S90-IR_1-300x208.png","contentUrl":"https:\/\/www.anjun.com.tw\/wp-content\/uploads\/2019\/01\/S90-IR_1-300x208.png"},{"@type":"BreadcrumbList","@id":"https:\/\/www.anjun.com.tw\/%e9%9b%b7%e5%b0%84\/%e9%9b%b7%e5%b0%84%e9%80%b1%e9%82%8a%e8%a8%ad%e5%82%99%e9%8a%b7%e5%94%ae\/solar-ls%e9%9b%b7%e5%b0%84\/spectral-instruments\/compact-spectrometers\/compact-ir-spectrometer\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9801","item":"https:\/\/www.anjun.com.tw\/"},{"@type":"ListItem","position":2,"name":"\u96f7\u5c04","item":"https:\/\/www.anjun.com.tw\/%e9%9b%b7%e5%b0%84\/"},{"@type":"ListItem","position":3,"name":"\u96f7\u5c04\u9031\u908a\u8a2d\u5099\u92b7\u552e","item":"https:\/\/www.anjun.com.tw\/%e9%9b%b7%e5%b0%84\/%e9%9b%b7%e5%b0%84%e9%80%b1%e9%82%8a%e8%a8%ad%e5%82%99%e9%8a%b7%e5%94%ae\/"},{"@type":"ListItem","position":4,"name":"SOLAR LS\u96f7\u5c04","item":"https:\/\/www.anjun.com.tw\/%e9%9b%b7%e5%b0%84\/%e9%9b%b7%e5%b0%84%e9%80%b1%e9%82%8a%e8%a8%ad%e5%82%99%e9%8a%b7%e5%94%ae\/solar-ls%e9%9b%b7%e5%b0%84\/"},{"@type":"ListItem","position":5,"name":"SPECTRAL INSTRUMENTS","item":"https:\/\/www.anjun.com.tw\/%e9%9b%b7%e5%b0%84\/%e9%9b%b7%e5%b0%84%e9%80%b1%e9%82%8a%e8%a8%ad%e5%82%99%e9%8a%b7%e5%94%ae\/solar-ls%e9%9b%b7%e5%b0%84\/spectral-instruments\/"},{"@type":"ListItem","position":6,"name":"COMPACT SPECTROMETERS","item":"https:\/\/www.anjun.com.tw\/%e9%9b%b7%e5%b0%84\/%e9%9b%b7%e5%b0%84%e9%80%b1%e9%82%8a%e8%a8%ad%e5%82%99%e9%8a%b7%e5%94%ae\/solar-ls%e9%9b%b7%e5%b0%84\/spectral-instruments\/compact-spectrometers\/"},{"@type":"ListItem","position":7,"name":"COMPACT IR-SPECTROMETER"}]},{"@type":"WebSite","@id":"https:\/\/www.anjun.com.tw\/#website","url":"https:\/\/www.anjun.com.tw\/","name":"\u5b89\u5747\u79d1\u6280\u6709\u9650\u516c\u53f8","description":"ANJUN TECHNOLOGY CO., LTD.","publisher":{"@id":"https:\/\/www.anjun.com.tw\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.anjun.com.tw\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.anjun.com.tw\/#organization","name":"\u5b89\u5747\u79d1\u6280\u6709\u9650\u516c\u53f8","url":"https:\/\/www.anjun.com.tw\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.anjun.com.tw\/#\/schema\/logo\/image\/","url":"https:\/\/www.anjun.com.tw\/wp-content\/uploads\/2021\/08\/\u65b0LOGO123-03-1.png","contentUrl":"https:\/\/www.anjun.com.tw\/wp-content\/uploads\/2021\/08\/\u65b0LOGO123-03-1.png","width":1000,"height":485,"caption":"\u5b89\u5747\u79d1\u6280\u6709\u9650\u516c\u53f8"},"image":{"@id":"https:\/\/www.anjun.com.tw\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.anjun.com.tw\/en\/wp-json\/wp\/v2\/pages\/1164","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.anjun.com.tw\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.anjun.com.tw\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.anjun.com.tw\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.anjun.com.tw\/en\/wp-json\/wp\/v2\/comments?post=1164"}],"version-history":[{"count":0,"href":"https:\/\/www.anjun.com.tw\/en\/wp-json\/wp\/v2\/pages\/1164\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.anjun.com.tw\/en\/wp-json\/wp\/v2\/pages\/1117"}],"wp:attachment":[{"href":"https:\/\/www.anjun.com.tw\/en\/wp-json\/wp\/v2\/media?parent=1164"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}